The Simplex PowerStar 110R is a portable resistive load bank rental, designed for manufacturers, dealers and users of small AC power systems. It is suitable for testing engine generators, wind generators, UPS systems, ground power units, auxiliary power units, static inverters or virtually any other AC power source on the production line, in the service shop or in the field. It can be applied at all common AC voltages to 480V maximum, 50 or 60 Hertz, single or 3-phase. The PowerStar is a digitally controlled load bank with network capability. Control is via a hand-held touchscreen controller connected to the load bank via a supplied RS-232 network cable. An aluminum "slip-over" cover with handles adds protection while transporting.
|
• | |
• | Digital load control, 5kw resolution |
• | Digital power transducer with volts, amps, frequency, and kilowatt meter displays on the touchscreen |
• | Mulitple Powerstar Load Banks can be networked together via RS-232 cables connected from the “out” connector on the first unit to the “in” connector on the next, and then “out-to-in” in succession until the desired number of units are connected |
• | All control and metering is provided from a single hand-held controller |
• | Operate fan and control circuits from a common 120V wall outlet, 15’ cord provided |
• | All instrumentation values for the total network are summed and displayed on the master controller |
• | “Powr-Web” elements |
• | Branch circuit fuse protection of load elements |
• | Magnetic contactor control of load |
• | Use at all common 50 or 60 Hertz voltages, to 480V AC |
• | Cam-Lok power connectors |
• | Forced air cooled, integral cooling fans |
• | Fan motors protected by fuses |
• | Control circuits fused |
• | Highly portable and easily transported to the job site |
• | Comprehensive malfunction detection system: |
| - Overtemperature and fan failure protection |
| - Overvoltage protection |
• | Continuous duty |
• | Type-1 enclosure |
• | Casters and handles provided |
Load Type |
Resistive |
Capacity |
110KW at 240/480V, 82.5KW at 208/416V, 73.3 at 240V, 1-ph |
Power Factor |
1.0 |
Voltages |
Dual Voltage, nominal 240/480V AC, 3-phase
208-240 / 416-480V AC, 3-phase, 60Hz
190-220 / 380-460V AC, 3-phase, 50Hz
110-240V AC, 1-phase, 50-60Hz |
Frequency |
50, 60 Hz |
Load Steps |
1KW |
Load Connection |
Cam-Type
|
Load Control |
Digital Controller
|
Cooling Airflow |
2400 CFM |
Fan/Control Power |
External 115V AC, 1Ø, 60Hz, 15A service, 15′ cord with plug provided |
Duty Cycle |
Continuous |
Portability |
Casters |
Options |
NEMA plugs, Cam-Type connectors, clamps |
Weight |
125 lbs |
Dimensions |
15″W x 31″H x 26″D |
Full Load Amps |
264 at 240V, 132 at 480V |
Temperature Rating |
Maximum Air Intake Temperature: 125° F |
Nominal Temperature Rise |
110° F |
Networkable |
Yes – other PowerStars only |
Outdoor Suitable |
No |
|