The Simplex Titan-600 R is a large capacity, fully portable, resistive/reactive Load Bank System intended for field use in testing, maintenance and performance proving of large generating systems. The Titan-600 R is rated 600kw, 750kvar and is user configurable for operation at 240/480v. The Titan-600R is typically used to test large diesel generators, turbines, paralleled generators and shipboard generators.
|
General
Load Elements
• | Simplex Powr-Web chromium alloy, open wire, continuously supported, power resistor. |
• | Elements mounted in slide-out trays. |
• | Resistive and inductive loads controlled separately to permit power factor variation. |
• | Rack mounted inductive load elements. |
• | UL Recognized. |
System Controls
• | Standard: Simplex D-Series Digital Controller with local or remote touchscreen. |
• | Remote operator interface terminal and user programmable automatic test routines. |
Cooling
System Protections
• | Sensors, alarms (alarm message on remote operator interface terminal), lock-outs as appropriate, for the following: fan failure, high exhaust temperature, high intake temperature. |
• | Over temperature switch embedded in coils. |
• | Load Circuit Protection: branch circuit fuses. Fuses are current limiting type, 200,000 AIC, 600V, enabling safe use on large generating or UPS system. |
Load Control
• | Branch circuit contactors, each 50KW step. |
• | Contactors with enclosed silver surfaced contacts, 120V coils; electrically operated and electrically held. |
Connections
• | Control Wiring: 105°C, color coded. |
• | Power Wiring: 150°C XLP color-coded. |
• | Cables connect to full rated copper bus bar with an oversized terminal junction box. |
Enclosure
• | Enclosure abrasively blasted or chemically etched, primed and finished, except exhaust hood which is unpainted, galvanized steel. |
• | Anti-condensation heaters at 120V, 1ø, 240V 1ø, or any common 3ø voltage. |
Load Type |
Reactive |
Capacity |
240/480v, 3-phase, 60 hertz:
750kva, 0.8 power factor
600kw resistive, 450kvar inductive, 1803/901A
208/416v, 3-phase, 60 hertz:
562.5kva, 0.8 power factor
450kw resistive, 337.5kvar inductive, 1563/781A81AW |
Power Factor |
Adjustable |
Voltages |
40/480v, 3-phase, 60 Hz |
Frequency |
60 Hz |
Load Steps |
Digital load control, 5 kw, 3.75 kvar resolution |
Load Connection |
Cam-Type on front panel
|
Load Control |
Remote operator interface terminal and user programmable automatic test routines
|
Cooling Airflow |
Vertical, approx 25,000 cfm divided between two cooling fans |
Control Power |
Internal, derived from power source under load, 240/480v, 3-phase, 60 Hertz.
Control circuits at 120v via internal isolation transformer. Fan motor load: 2 x 5hp, 26/13A. |
Control Power Load |
3.0 kva, 6.25A |
Duty Cycle |
Continuous |
Portability |
Fork lift channels, lifting eyes, tie-down D rings, trailerable |
Networkable |
Yes |
Outdoor Suitable |
Yes |
|