|
The Simplex SST Series comprises a line of fuel tanks at capacities of 10 and 25 gallons. The standard SST package includes a UL 142 listed tank, a 2 GPM Super-XL Pump, and a UL 508 listed Analog Controller.
The SST Series is fully compatible for network integration with the full line of Simplex Fuel Supply Systems, including packaged pump systems, tank filling systems, filtration systems, digital fuel and tank management systems and digital monitoring and data systems. The SST Series, when supplied with a Simplex digital controller, is MODBUS and Ethernet compatible with most tank gauging systems.
|
• | The SST Series is comprised of highly reliabile 10 and 25 gallon fuel tanks used as day tanks, main supply tanks, transfer tanks, return tanks, and filter tanks. Manual tanks for use as a basic storage tanks are also available. |
• | The SST Series is fully compatible for network integration with the full line of Simplex Fuel Supply Systems, including packaged pump systems, tank filling systems, filtration systems, digital fuel and tank management systems and digital monitoring and data systems. |
• | SST fuel tanks are UL 142 labeled double-walled, suitable for indoor or outdoor use. |
• | Controllers for normal duty products are UL508 listed, Type 1 indoor, Type 3R, 4, 12 indoor/outdoor. Hazardous location controllers are available. |
• | Codes and standards: City of Chicago approval #E9135, #E9136; L.A.F.D. Approval - Los Angeles Fire Department approved day tanks - use SST/SRS Series Day Tank; Wisconsin approval #940065U; and Florida EQ #732. |
• | The SST Series integrates a tank of required capacity with a level controller and fill control. On-board fill pumps and return pumps are typical. Remote pumping systems are available for filling of multiple tanks, management of multiple source tanks or when required by pipe run or pump size conditions. |
• | Both digital and analog controllers are available. Digital controllers are PLC based and network compatible. Digital controllers utilize both a point sensing float switch input and a 4-20mA analog to-digital input which displays on a panel indicator and provides a 4-20mA output. Analog controllers are based on the time-proven Simplex SST Controller. |
Capacities |
10 gallons and 25 gallons |
Product |
Class II Liquid, > 100°F Flash Point |
Control |
UL508 Digital PLC Based controller, network compatible UL508 Analog Level Controller |
Pumps |
2-50 GPM, 0.33-5.0 HP, Single or 3-Phase |
Motors |
Industrial NEMA size, conservatively rated, all commercial voltage ratings |
Construction |
Suitable for indoor or outdoor installation 12 GA HRS |
Listing |
UL142 Double-Wall |
Rating |
Atmospheric tank tested to 3 PSI |
Finish |
UL Listed powder-coat process |
Typical Fittings |
Engine Supply Drop Tube, 0.75" NPT Male Siphon Drain Drop Tube, 0.75" NPT Male Overflow Port, 2.00" NPT Female Engine Return Port, 1.00" NPT Female Extra Pipe Flange, 1.00" NPT Female Tank Vent Port, 2.00" NPT Female Manual Fill Drop Tube, 2.00" NPT Male Hand Pump Mounting Drop Tube, 0.75" NPT Male Pump Connection to Tank Drop Tube, 0.75" NPT Female Floatswitch MTG/Inspection Port, 1.00" NPT Female Containment Basin Drain, 0.375" NPT Female |
Dimensions |
10 Gallon - 24"W x 28.5"H x 16"D 25 Gallon - 24"W x 41"H x 16"D
Tank with Optional UL142 Secondary Containment 10 Gallon - 31"W x 32"H x 26"D 25 Gallon - 31"W x 44.5"H x 26"D
Note: Add 9.5" to H for duplex pump. Dimensions are subject to change with options selected. |
Mechanical |
Option 010, 015, Auxiliary Hand Pump, is recommended for installation on all Day Tanks equipped with motor-pumps. The hand pump is used for initial priming of the fuel line from the main tank and as a backup to the motor-pump.
Option 060, 062 Fuel Strainer, is recommended whenever there is a possibility of fuel contamination. Day Tank pumps have extremely close tolerances. Fine abrasives in suspension degrade pumping ability and can jam pump.
In order to assure maintenance of pump prime, one of the following options is recommended for installation on all Day Tanks equipped with motor-pumps: Option 070: Check valve; Option 080, 083: Solenoid valve; or Option 090: Foot valve.
OPT - Description
010 - Auxiliary hand pump, 1 GPM capacity, 1/2" NPT (Side mounted)
015 - Auxiliary hand pump, 20 gallons per 100 strokes, 1" NPT (Side mounted)
025 - Locking manual fuel fill cap
040 - Wall-mounting brackets
050 - Pipe stand adapter
060 - Fuel strainer
062 - Duplex strainer
063 - Vent cap
064 - Emergency vent
065 - Drain hand valve
067 - Flame arrestor vent
068 - Emergency quick-drain
070 - Check valve/priming tee assembly
080 - Solenoid valve
083 - DC Solenoid Valve
087 - Manual fuel shut-off valve, bronze
088 - Manual fuel shut-off valve, fire-rated
090 - Foot valve
093 - Fusible link valve
095 - Pressure relief valve
100 - Pressure gauge
101 - Vacuum gauge
103 - Flow gauge in line with pump, to 29 GPM
104 - Flow indicator sight glass
105 - Temperature gauge
120 - Extra 1" pipe connection
125 - Extra engine suction standpipe
130 - Oversize pipe connections, 1 1/4" to 2 1/2" NPT
131 - Oversize pipe connections, 3” to 6” NPT
140 - Special paint colors
141 - Epoxy primer, centurian finish
180 - Weatherproof modification |
Tank Containments |
OPT - Description
190 - Secondary containment basin
191 - Float switch in rupture basin with alarm
192 - Containment drain valve
195 - Screen for top of containment basin
196 - Weatherproof cover for containment basin
|
Control Devices and Alarms |
OPT - Description
260 - Disconnect switch
261 - System circuit breaker
262 - Control power transformer
265 - Tank heater
270 - Power available green pilot light
280 - Operation mode selector
285 - Loss of flow alarm
295 - Remote low fuel level alarm
297 - Remote high fuel level alarm
299 - Auxiliary relay
311 - Local/remote low fuel level alarm
312 - Local/remote high fuel level alarm
325 - High fuel level emergency pump stop switch
326 - High level cut-out
329 - Low fuel level red light
333 - Critical low fuel alarm
334 - Alarm horn
340 - Running Pump amber light |
Duplex Pump Systems |
Duplex pump options are used to increase the reliability of a day tank system through the addition of a second, backup pump and level control. In a duplex system, one pump is designated the “lead” pump and the other is the “lag” pump. The lead pump automatically refills the day tank over the tank’s normal operating range of 50% to full. Normally, once the tank has been initially filled, the fuel level should never drop below 50%. Less than 50% is indicative of either a failure of the lead pump or consumption in excess of pump capacity. The lag pump and its separate level controller, acting as a backup senses a drop in fuel level below 50% and starts the lag pump, which then continues to run, along with the lead pump, until the tank is full.
When ordering, remember that duplex systems include two motor-pumps and therefore require a quantity of two of any option related to the motor or pump, such as solenoid valves, strainers, etc.
OPT - Description
345 - Duplex pump controller
346 - Two running time meters
347 - Manual duplex pump selector switch
349 - Basic PLC based level and duplex pump controller (replaces analog controller) |
Gravity Fed Tanks |
A day tank will be gravity-siphon fed when:
1) The main tank is above the day tank.
2) The main tank is on the approximate same grade as the day tank and the level in the main tank is at times above the level in the day tank and/or supply piping runs overhead.
If any of these conditions exists, a positive fuel shut-off automatic control must be added to the day tank. Simplex recommends options 060, 080, 087, 376, 377, and 190/191 for all gravity-fed systems. Add options 383 and 390 as an additional precaution.
OPT - Description
060, 080, 087 - Solenoid valve, with fuel strainer
376 - Manual reset, normally open solenoid valve
377 - Siphon-break solenoid valve
378 - Anti-siphon valve, 2"
383 - Automatic pump-out conversion
390 - Fuel rise pump-out control
190 - Secondary containment basin
191 - Float switch in rupture basin with alarm
215 - Mechanical dial level gauge
067 - Flame arrestor vent, 2" |
Fuel Oil Coolers (Installed in Return Line) |
OPT - Description
396 - Radiator, fan, motor, flow switch, and control panel, installed and wired on day tank |
Pumps (HP is minimum motor size) |
Series XL Pumps (cast aluminum)
OPT - Description
399 - 2 GPM, 1/3 HP (standard)
404 - 4 GPM, 1/3 HP
407 - 7 GPM, 1/2 HP
410 - 10 GPM, 3/4 HP
417 - 17 GPM, 1 HP
425 - 25 GPM, 1 1/2 HP
Series 500 Pumps (cast iron)
OPT - Description
501 - 1 GPM, 1/3 HP
502 - 2 GPM, 1/2 HP
505 - 5 GPM, 1/2 HP
507 - 7 GPM, 1/2 HP
510 - 10 GPM, 3/4 HP
515 - 15 GPM, 1 HP
520 - 20 GPM, 1 1/2 HP
529 - 29 GPM, 1 1/2 HP
532 - 32 GPM, 2 HP
542 - 42 GPM, 3 HP
548 - 48 GPM, 5 HP
552 - 52 GPM, 5 HP |
Motors |
OPT - Description
600 - 1/2 HP, 115V AC, 1-PH, 60Hz, ODP
605 - 1/3 HP, 230V AC, 1-PH, 60Hz, ODP
615 - 1/3 HP, 110V AC, 1-PH, 50Hz, ODP
616 - 1/3 HP, 220V AC, 1-PH,50Hz, ODP
621 - 1/3 HP, 230/460V AC, 3-PH, ODP, w/starter
622 - 1/3 HP, 230/460V AC, 3-PH, TEFC, w/starter
630 - 1/3 HP, 12V DC
635 - 11/3 HP, 24V DC
645 - 1/3 HP, 115V AC, 1-PH, 60Hz, TEFC
700 - 1/2 HP, 115V AC, 1-PH, 60Hz, ODP
705 - 1/2 HP, 230V AC, 1-PH, 60Hz, ODP
715 - 1/2 HP, 110V AC, 1-PH, 50Hz, ODP
716 - 1/2 HP, 220V AC, 1-PH, 50Hz, ODP
721 - 1/2 HP, 230/460V AC, 3-PH, ODP
722 - 1/2 HP, 230/460V AC, 3-PH, TEFC, w/starter
730 - 1/2 HP, 12V DC
735 - 1/2 HP, 24V DC
745 - 1/2 HP, 230/115V AC, 1-PH, 60Hz, TEFC
800 - 3/4 HP, 115V AC, 1-PH, 60Hz, ODP
805 - 3/4 HP, 230V AC, 1-PH, 60Hz, ODP
822 - 3/4 HP, 230/460V AC, 3-PH, 60Hz, TEFC
825 - 3/4 HP, 230/460V AC, 3-PH, 60Hz, ODP, w/starter
845 - 3/4 HP, 115/230V AC, 1-PH, 60Hz, TEFC
900 - 1 HP, 115V AC, 1-PH, 60Hz, ODP
905 - 1 HP, 230V AC, 1-PH, 60Hz, ODP
922 - 1 HP, 230/460V AC, 3-PH, 60Hz, TEFC
925 - 1 HP, 230/460V AC, 3-PH, 60Hz, ODP, w/starter
945 - 1 HP, 115/230V AC, 1-PH, 60Hz, TEFC
3-PH motors may be operated at 190/380V; 50Hz. 50Hz operation reduces pump capacity by 5/6.
|
Motors Requiring SPS/SKS Pump Set |
OPT - Description
1022 - 1 1/2 HP, 230/460V AC, 3-PH, 60Hz, TEFC, w/starter
1025 - 1 1/2 HP, 230/460V AC, 3-PH, 60Hz, ODP, w/starter
1045 - 1 1/2 HP, 115/230V AC, 1-PH, 60Hz, TEFC
1122 - 2 HP, 230/460V AC, 3-PH, TEFC, w/starter
1125 - 2 HP, 230/460V AC, 3-PH, 60Hz, ODP, w/starter
1145 - 3 HP, 115/230V AC, 1-PH, 60Hz, TEFC
1205 - 3 HP, 230V AC, 1-PH, 60Hz, ODP
1225 - 3 HP, 230/460V AC, 3-PH, 60Hz, ODP, w/starter
1305 - 5 HP, 230V AC, 1-PH, 60Hz, ODP
1322 - 5 HP, 230V AC, 3-PH, 60Hz, TEFC
1325 - 5 HP, 230/460V AC, 3-PH, 60Hz, ODP, w/starter
1422 - 71/2 HP, 208V AC, 3-PH, 60Hz, ODP
1425 - 71/2 HP, 230/460V AC, 3-PH, 60Hz, ODP, w/starter
3-PH motors may be operated at 190/380V; 50Hz. 50Hz operation reduces pump capacity by 5/6.
|
Motors Starters |
OPT - Description
768 - Single phase magnetic motor starter
770 - 3-phase magnetic motor starter
|
Note: We are experts at building products that meet our customer's exact requirements. Contact Simplex if your job specifications require additional options or considerations.
|