Page 19 - Load Bank Rentals
P. 19

Infinity-200R


                                                                                       200 KW Digital Load Bank
                                                                                         with Network Capability


                                                         Rental Duty
                                                  Dual Voltage Load Bank
                                                    208-240/416-480vAC
            Overview

            •  Infinitely variable: 0-200kw, 208-480v
            •  Infinitely flexible: compact, lightweight,
             flush sides, 360-degree casters
            •  Infinitely expandable: digitally network
             to as many as 40 Infinity or Powerstar
             load banks
            Description

            The new Simplex Infinity 200 is simply
            the most advanced factory-standard
            load bank available anywhere. Digitally
            controlled infinite loads—simply enter
            any value from zero to max, and the
            load bank goes there. Ramp-up,
            ramp-down, infinitely. Roll-in, roll-out,
            360-degree casters, forkliftable, connect
            up to 2 x 4/0 per phase. Daisy chain up
            to 40 units (that’s 8000kw- maybe not
            infinite capacity, but who’s counting at
            that point). Single-point control of the
            chain of load banks. Single-point data
            acquisition of the chain. 200kw at 240
            and 480v, 3-phase; 150kw at 208 and
            416v, 3-phase, 133kw at 240v, single-
            phase, all in the smallest and lightest   Infinity-200  or Powerstar Load Banks
            package available.                  can be networked together via RS-
            Upon initial start-up , the Infinity   232 cables connected from the “out”
            controller measures the applied voltage   connector on the first unit to the “in”   •  Magnetic contactor control of load
            and calibrates the loads to that voltage.   connector on the next, and then “out-  •  Digital load control
            Therefore, at intermediate voltages,   to-in” in succession until the desired   •  Use at all common 50 or 60 Hertz
            such as 440v, 416v, 220v, 208v, the   number of units are connected. All   voltages, to 480V AC
            load bank controller calibrates for the   control and metering is provided
            reduced capacity. Within the capacity of   from a single hand-held controller. All   •  Digital Power Transducer, standard:
            the load bank, the load requested is the   instrumentation values for the total   Volts, Amps, Frequency, Kw
            load applied.                       network are summed and displayed on   •  150°C XLP insulated power wiring
                                                the master controller.
            Also, the Infinity-200 is compatible with                               •  Cam-Type power connectors
            the Simplex Powerstar-110—daisy     The Infinity-200 is highly portable and   •  Operate fan and control circuits from
            chain any combination of Infinitys and   easily transported to the job site. The   a common 120V wall outlet, 15’ cord
            Powerstars.                         Load Bank includes casters, lifting and   provided
                                                moving handles. Power connections are
            The Infinity-200 is a digitally controlled   plug-in to Cam-Type connectors. Control   •  Forced air cooled, integral cooling
            load bank with network capability. All   and cooling fan power is obtained from   fans
            control is via a hand-held touchscreen   a common 115v, 15A outlet via the   •  Fan motors protected by fuses
            controller connected to the load bank   included connection cord.       •  Control circuits fused
            via a supplied RS-232 network cable.
            The load bank includes a digital    Features                            •  Comprehensive malfunction detection
            power transducer with meter displays                                     system:
            on the touchscreen. Load is applied   •  Unique compact 200kw load bank    -  Overtemperature and fan failure
            via a screen keypad. Any number of   •  Lightweight and compact            protection
                                                •  Portable, self-contained           -  Overvoltage protection
                                                •  “Powr-Web” elements              •  Continuous duty
                                                •  Branch circuit fuse protection of load   •  NEMA-1 enclosure
                                                 elements                           •  Casters and handles provided



            © 2021 Simplex, Inc.  All Rights Reserved.  SIMPLEX INC.
            Printed in the USA  •  2103-02.00  •  Page 19  5300 Rising Moon Road, Springfield, IL 62711 • simplexdirect.com • 800-637-8603
            Design subject to change without notice.  Nationwide Manufacturing (ISO9001: 2015 certified)
   14   15   16   17   18   19   20   21   22   23   24