Page 42 - Load Bank Rentals
P. 42

Trident 2500R                                                                                              ®

        Digital Load Bank with Data Acquisition
        1500KW - 2500KW                                                                              Insight     Onsite






























         Capacity Detail

                         TOTAL                                       KW DETAIL
          Model         KW (1.0pf)     480V         416V         380V         240V         208V       240V, 1-ph*
          Trident 1500    1500         1500          1125         940          1000         750          300
          Trident 1800    1800         1800         1350          1128         1000         750          300
          Trident 2000    2000         2000         1500          1253         1000         750          300

          Trident 2250    2250         2250         1688          1410         1000         750          300
          Trident 2500    2500         2500         1875          1567         1000         750          300
         *Requires external 3-phase fan/control power. Capacity limited to 1250 FLA.


         Voltage: Dual Voltage: 240/480V AC,   Airflow:  42,000 CFM              Digital Load Control
         3-phase Operational at any voltage to
         480V AC maximum, single or 3-phase  Temperature Rise:  180°F nominal    Nominal 5.0 kw resolution: direct enter
         Optional Voltages: Instead of 240/480v   Control/Fan Power:             any load value and controller will apply
         dual voltage:                       •  230/460V, 3-phase, 60 Hertz      load within nominal 5kw resolution
         a. Any 50hz or 60hz single voltage to 690v  •  190/380V, 3-phase, 50 Hertz  Digital Load Calibration
         b. 600v, single voltage             •  Switchable internal (generator)-   Versus Voltage
         c. 600/480v, dual voltage             external
         d. 600/300v, dual voltage           •  External fan/control power       Controller automatically calibrates loads
         e. 480/416v, dual voltage             requirements: 240/480vAC, 3-phase,   for reduced voltage operation.
                                               60 Hertz, 80 / 40  amps service
         f.  208/416v, dual voltage            (7.5HP motor)
         Frequency: 50, 60 Hertz standard    •  230/460-115V control power
                                               transformer internal to Load Bank.
         Connection: 3-wire plus ground
                                             Net Weight:  Approx. 12,500 lbs.,
         Time Rating:  Continuous            including load module, trailer, three
         Ambient Air Temperature:  120°F max  reels, 2000’ 4/0 cable, cam-lock style
                                             connectors





        SIMPLEX INC.                                                               © 2021 Simplex, Inc.  All Rights Reserved.
        5300 Rising Moon Road, Springfield, IL 62711 • simplexdirect.com • 800-637-8603  Printed in the USA  •  2103-02.00  •  Page 42
        Nationwide Manufacturing (ISO9001: 2015 certified)                         Design subject to change without notice.
   37   38   39   40   41   42   43   44   45   46   47