Titan 600R Load Bank Rental

Overview

The Simplex Titan-600 R is a large capacity, fully portable, resistive/reactive Load Bank System intended for field use in testing, maintenance and performance proving of large generating systems. The Titan-600 R is rated 600kw, 750kvar and is user configurable for operation at 240/480v. The Titan-600R is typically used to test large diesel generators, turbines, paralleled generators and shipboard generators.

We are experts at building products that meet our customer's exact requirements. Contact Simplex if your job specifications require additional options or considerations.

Features

General

Load Elements

  • Simplex Powr-Web chromium alloy, open wire, continuously supported, power resistor.
  • Elements mounted in slide-out trays.
  • Resistive and inductive loads controlled separately to permit power factor variation.
  • Rack mounted inductive load elements.
  • UL Recognized.

System Controls

  • Standard: Simplex D-Series Digital Controller with local or remote touchscreen.
  • Remote operator interface terminal and user programmable automatic test routines.

Cooling

System Protections

  • Sensors, alarms (alarm message on remote operator interface terminal), lockouts as appropriate, for the following: fan failure, high exhaust temperature, high intake temperature.
  • Over temperature switch embedded in coils.
  • Load Circuit Protection: branch circuit fuses. Fuses are current limiting type, 200,000 AIC, 600V, enabling safe use on large generating or UPS system.

Load Control

  • Branch circuit contactors, each 50KW step.
  • Contactors with enclosed silver surfaced contacts, 120V coils; electrically operated and electrically held.

Connections

  • Control Wiring: 105°C, color coded.
  • Power Wiring: 150°C XLP color-coded.
  • Cables connect to full rated copper bus bar with an oversized terminal junction box.

Enclosure

  • Enclosure abrasively blasted or chemically etched, primed and finished, except exhaust hood which is unpainted, galvanized steel.
  • Anti-condensation heaters at 120V, 1ø, 240V 1ø, or any common 3ø voltage.

Specifications

Load TypeReactive
Capacity240/480v, 3-phase, 60 hertz:
750kva, 0.8 power factor
600kw resistive, 450kvar inductive, 1803/901A
208/416v, 3-phase, 60 hertz:
562.5kva, 0.8 power factor
450kw resistive, 337.5kvar inductive, 1563/781A81AW
Power FactorAdjustable
Voltages40/480v, 3-phase, 60 Hz
Frequency60 Hz
Load StepsDigital load control, 5 kw, 3.75 kvar resolution
Load ConnectionCam-Type on front panel
Load ControlRemote operator interface terminal and user programmable automatic test routines
Cooling AirflowVertical, approx 25,000 cfm divided between two cooling fans
Control PowerInternal, derived from power source under load, 240/480v, 3-phase, 60 Hertz.
Control circuits at 120v via internal isolation transformer. Fan motor load: 2 x 5hp, 26/13A.
Control Power Load3.0 kva, 6.25A
Duty CycleContinuous
PortabilityFork lift channels, lifting eyes, tie-down D rings, trailerable
NetworkableYes
Outdoor SuitableYes

This website stores cookies on your computer. These cookies are used to collect information about how you interact with our website and allow us to remember you. We use this information in order to improve and customize your browsing experience and for analytics and metrics about our visitors both on this website and other media. To find out more about the cookies we use, see our Privacy Policy.