Saturn
Load Bank

The Saturn Load Bank is a completely self-contained, freestanding unit which includes all resistive load elements, load control devices, load element branch circuit fuse protection, main load bus and terminals, cooling system, control power supply, unit controller and malfunction detection system and NEMA type enclosure.

The Saturn pictured at right is an indoor configuration. An exhaust hood is required for exterior use.

Ultra-high capacity load testing of generators or electric dynamometer testing of large engines and turbines is achieved with the Simplex Saturn Load Bank. The unit capacity range of the Saturn is 1500-3000KW, resistive, unity power factor. Saturns may be used singly or in systems of multiple units which yield total capacities of tens or hundreds of megawatts.

The Saturn is a single or dual voltage Load Bank suitable for all common 60 and 50 Hertz voltages up to 600V. Loads are stepped in any increment of 50KW, or, optionally, in fixed steps to 5KW or infinitely variable.

Cooling System: Using an ultra high volume forced air cooling system, up to 60,000CFM for the 3000KW Saturn, air temperature rise is limited to that seen in smaller Load Banks, in the 150-200°F range.

Load Control: Master load toggle switch and load step toggle switches

Simplex Load Banks can be used to satisfy the requirements of the National Fire Protection Association (NFPA) for emergency stand-by power systems.

Saturn Stationary Load Bank

Features

Self-contained load and control system

Utilizes the UL Recognized, “Powr-Web” load element

Branch circuit fuse protection of load elements

Color coded and numbered wiring; power wiring 150°C

Plated bus bar

Benefits

Modular enclosure design with separate and isolated control and power sections

NEMA-3R, oversize control section with generous cable connection space

Vertical airflow, exhausts hot air above level of personnel and away from buildings, pavement etc.

Comprehensive overload, short circuit and malfunction protection

Slide-out, tray mounted load elements

Highly standardized, based upon extensive product line spanning from 5KW to 3MW
GENERAL SPECIFICATIONS

Capacity
1500KW, 1800KW, 2000KW, 2500KW,
3000KW; Resistive, 1.0 power factor

Voltage
All common 3-phase
60 and 50 Hz voltages:
60 Hertz: 208V, 220V, 240V, 416V, 440V, 450V, 460V, 480V, 575V, 600V
50 Hertz: 190V, 200V, 208V, 380V, 400V, 416V

Frequency
50, 60 Hertz

Load Steps
50 KW resolution standard
1-5-10-25KW resolution available

Fan/Control
Internal, from load bus. Control circuits at 120V via transformer. The cooling fan operates at 3-phase line voltage. Load control circuits and fan motor control operate at 120V. Control circuits are fused. Control circuit fuses are 100,000 A.I.C., 600V rated. External, 480/240V, supply for humidity controller, when ordered.

Cooling
1500-1800KW: 40,000 CFM
1800-2000KW: 50,000 CFM
2500-3000KW: 60,000 CFM

Duty Cycle
Continuous

Sales Bulletin
 
Dimensions and Key Features Diagram


Stationary Load Banks:
Applications and General Specifications, Features and Options, and Engineer’s Specifications

 
 

Powr-Web Load Element

Powr-Web Load Elements

Simplex Load Banks utilize the UL Recognized, “Powr-Web” load element. The “Powr-Web” is an advanced design, air-cooled power resistor specifically designed for application to load bank systems. The “Powr-Web” is conservatively operated at half the maximum temperature rating of the alloy and features a short-circuit-safe design based on continuous mechanical support of the resistor by high temperature, ceramic clad stainless steel rods. The “Power Webs” are assembled into discrete trays which are assembled in a vertical “stack.” Each tray in the “stack” is independently serviceable without disturbing adjacent trays.

Ratings
3333W at 120V
4170W at 139V
8333 watt 240/480V
16,777 watt at 480V

Specifications
Alloy: FeCrAl
Max. continuous temp. rating: 1920°F
Maximum operating temperature as applied in Load Bank: 1080° F
Cool down time from operating to ambient temperature: 10 seconds

Powr-Web Load Element Tray

Construction
Calibrated to specific ohm value
Welded lugs on each end
All load elements are continuously supported by vibration resistant, ceramic clad, stainless steel throughrods

Branch Circuit FusesBranch Circuit Fuse Protection

The load of a Resistive Load Bank consists of a dense array of open, uninsulated power resistors mounted within a cooling air stream. Since the elements are electrically live, it is possible for a foreign object to penetrate the element array and create a short circuit of adjacent elements or a short to ground. Since the elements are densely packed, it is possible for a short circuit, once started, to rapidly propagate through the entire element array. As a Load Bank represents a relatively large amount of power concentrated within a relatively small volume, a self-propagating, cascading short circuit would have catastrophic results.

Simplex virtually eliminates the dangers of short circuit through the use of branch circuit fuse protection of the load elements. Per NEC 110-10, protective devices shall clear a fault without “extensive damage” to the circuit components. A Simplex Load Bank is divided into branch circuits of not more than 50 KW each.
 

 

Principle Systems and Components

  Load Elements
Simplex “Powr-Web” open wire, helically wound, chromium alloy, thermally derated to 60%. 5% tolerance, 2% balance, .995 p.f.
UL Recognized.

Load Control
Branch circuit contactors, each 50 KW step. Contactors have enclosed silver surfaced contacts, 120V coils; electrically operated and electrically held.

Element Circuit Protection
Branch circuit fuses, each 50KW branch circuit, 70A, 200kAIC, current limiting type.

Temperature
Maximum ambient temperature: 125°F
Exhaust rise: RISE = KW X 3000/CFM (note: as airflow is not laminar, exhaust air temperatures are not equal at all points at the plane of air exhaust. Some parcels of air may reach approximately 575°F before mixing.)

System Protection
Fan failure, high exhaust temperature, high intake temperature; lockout and alarm.

 
Enclosure

Modular enclosure consists of three parts:

1. NEMA-3R rainproof power section including load elements and cooling fan

2. NEMA-3R control section, thermally and electrically isolated from power section

3. Exhaust hood. Mounts atop power section. Vertical flow with rain separators. Hood may be deleted and a duct flange provided for indoor applications where air is exhausted through a duct to the outdoors.

All panels for access to serviceable components are hinged doors with stainless steel hinges and lockable latches. All exterior fasteners are stainless steel.

The Load Bank enclosure is of double wall construction for cool exterior and thermal isolation of the load elements. Cooling airflow through the enclosure is vertical with cold air intake at the bottom and hot air exhaust out the top. Intake and exhaust openings are screened. All parts of the enclosure are abrasive blasted or chemically etched, primed and finished with a color as specified. The exhaust hood which is exposed to high air temperatures is unpainted galvanized steel.

 
 Saturn Stationary Load Bank control compartment

Power Wiring
150°C insulated; color coded.

Control Wiring
105°C, color coded and/or numbered.

Power Connection
Plated bus bar within an oversize terminal junction box.